当前位置: 首页/ 各期目录/ 文章详情
来源: 《安全与电磁兼容》2007年第2期 作者:刘晓东 张娴   吴燎兰 等(57)

工况可调屏蔽室的建立与应用
Installation and Application of a Climatic-conditioning Shielding Room


摘要 建立了工况可调电磁屏蔽室,实现了供电供水及大范围温湿度可调。采用干净变频电源,单相供电电压0~300V、频率10~80Hz、容量6kVA,三相供电电压0~500V、频率40~80Hz、容量20kVA;恒温恒湿系统的温度在10℃~35℃连续可调、湿度控制在30%~60%之间,满足了电磁兼容标准对试验环境气候条件要求的最大范围;加装了内循环给排水系统,可给被测设备提供恒温水;设计了电缆连接屏蔽漏斗,隔离屏蔽室内外测试仪器和被测设备。
关键词 屏蔽室;工况可调;传导骚扰
Abstract A climatic conditioning shielding room is installed to provide adjustable 
temperature and humidity. A clean single-phase alternating source provides (0~300)
V, (10~80)Hz, 6kVA; a clean three-phase alternating source provides (0~500)V、
(40~80)Hz、20kVA. The climate conditioning system provides adjustable temperature
between (10~35)℃ and humidity between (30~60)%, it meets those 
requirement for testing climate in relative standards. The water supply provides close-
cycle heated water.A shielding tundish is designed to connect the cables and isolate
instruments outside and EUT inside.
Keywords Shielding room; Climatic conditioning ;Conducted disturbance

网站会员需要登录才能在线预览,点我登录。

如何成为网站会员>>