电流阀值对断续骚扰检测结果的影响
Effect of Current Threshold Value in the Discontinuous Disturbance
Test
摘要 对于某些由开关操作数得出喀呖声率的被测设备,目前大部分检测实验室的断续骚扰分析仪可能会漏计算一些开关操作。解释了标准中“开关操作”的定义,通过实际案例阐述了使用分析仪进行断续骚扰项目检测时,预置电流阀值的选择对检测结果的影响。
关键词 断续骚扰;喀呖声;喀呖声率;开关操作;电流阀值
Abstract For some of the equipments under test, those click rate are derived from the
number of switching operation, some switching operations maybe omitted unavoidably
by the analyzer in most test laboratory. According to the definition of switching
operation in the standard, the paper introduces the threshold current value and its
effect to the discontinuous disturbance test result through the actual example.
Keywords discontinuous disturbance; click; click rate;switching operation; current
threshold value