房间电加热器浪涌抗扰度案例分析
Representative Case Analysis of Surge Immunity Test for Room
Electric Heater
摘要 以具有电容降压电路的房间电加热器浪涌抗扰度不合格的典型案例为研究对象,给出了详细的定位与验证分析过程,并提出了整改措施,即在整流桥输出到稳压二极管之间串联限流电阻。整改后,房间电加热器满足浪涌抗扰度要求,即火线对零线(差模)±1 kV,火线对地线(共模)±2 kV,零线对地线(共模)±2 kV。
关键词 电容降压电路;浪涌;抗扰度;电容
Abstract This paper researches on a representative case of susceptibility of room
electric heater to surge, which contains the capacitive step-down circuit. Detailed
analysis on locating and validating process are given,and the countermeasure,which
the series current-limiting resistance is bridged between rectifier and Zener diode,is
carried out to satisfy surge immunity requirement, namely adding ±1 kV surge
between phase line and neutral line (different mode) and ±2 kV surge between
neutral/phase line and ground line (common mode).
Keywords capacitive step-down circuit; surge; immunity; capacitor