产品接地不良案例
Analysis on the Poor Grounding for One Product


摘要 对某工程现场多台返修设备的故障情况进行了分析,找到了引起故障的主要原因是接地不良,并提出了相应的整改方案。改进后的产品抗干扰能力明显增强,满足工程要求。
关键词 产品设计;接地;整改
Abstract  The failure was analyzed for more than one damaged product from an 
engineering site, the design flaws that caused product failure was found to be a poor 
grounding, the corresponding corrective measures were put forward. The ability to 
resist interference of the corrected product was greatly enhanced.
Keywords  product design; grounding; correction