辐射电磁骚扰测量中归一化偏差分析
Analysis on the Deviation of Normalized Radiated Disturbance
Measurement Results
摘要 用3米法和10 米法半电波暗室测量辐射电磁骚扰时,在180~260 MHz 频段上应用20 dB/10倍的反比因子归一化测量结果存在一定的偏差。3 米法半电波暗室归一化后的结果偏小,导致最终被测试设备在3 米法半电波暗室测量会比在10 米法半电波暗室测量时,更容易满足辐射电磁骚扰的限值要求。分析了归一化偏差产生的原因,并提出了加入辅助的修正系数修正测试结果的方法。
关键词 偏差;辐射骚扰;反比因子;归一化;半电波暗室;CISPR 22
Abstract By using the method of inverse proportionality factor of 20 dB per decade,the
measurement results of radiated disturbance from 3 m test could be normalized to
reconstruct data as measured by 10 m test method.However,this method could produce
deviation in the frequency range of 180~260 MHz. Finally, the reason of deviation is
analyzed, and the correction method is put forward.
Keywords deviation; radiated disturbance; inverse proportionality factor; normalize; mi-anechoic chamber;CISPR 22
本期目录
- 谈汽车功能安全与电磁兼容 <...
- 2012 CISPR...
- 采用改进的标准场地法测量LPD...
- 辐射发射测试系统的期间核查统计...
- 欧盟电子、电气设备电磁场人体暴...
- VSAT和交互式卫星地球站设备...
- 复杂强电磁环境下系统辐射敏感度...
- 辐射电磁骚扰测量中归一化偏差分...
- 欧美对LED灯管的安全要求 ...
- 2.4 GHz终端设...
- 电动汽车轮速传感器信号失真整改...
- 电子产品静电放电失效分析与对策...
- 圆孔形FSS对复合材料吸波效能...
- 紫外光固化聚氨酯基功能涂层的研...
- 电源完整性设计中的谐振仿真 ...
- 基于CADENCE的IBIS模...
- LED光源视觉舒适度研究现状与...
- LED光源视觉舒适度典型参量与...
- EMC电波暗室新的设计考虑 ...
- 苏州电器科学研究院股份有限公司...
- 2012 IEEE&...
- 追求天线校准场地性能的10米法...