来源: 《安全与电磁兼容》2013年第2期 作者:柳光福 方国兴  要国伟

400 Hz屏蔽室滤波器与CE102测试
CE102 Test Related to Shielding Room Filters of 400 Hz


摘要 讨论了CE 102测试与400 Hz屏蔽室滤波器之间的问题,部分400 Hz屏蔽室滤波器不能把经过滤波器的电磁干扰抑制到允许的电平范围内,导致屏蔽室内传导环境电平不满足测试要求,使得 CE 102的测试结果出现较大误差;另一方面,400 Hz屏蔽室滤波器还会造成供电电压升高,影响CE102的测试结果。结合实际案例,分析得出多级滤波中的电容是电压抬升的主要原因,并给出了解决问题的建议。
关键词 400 Hz中频电源;屏蔽室滤波器;传导环境电平;电压升高;CE102
Abstract   The problems concerning CE102 test and shielding room filter for 400 Hz 
power supply are discussed. For example, the conducted emission environmental level 
can not meet the requirements, because the shielding room filter for 400 Hz power 
supply are not able to control electromagnetic interference voltage within the confines 
of allowable level. The filter also leads to power supply voltage rise, which may greatly 
affects test results. Finally, the countermeasures are suggested based on practical 
cases.
Keywords intermediate frequency power supply of 400 Hz;shielding room filter;
conducted emission environmental level; power supply voltage rise;CE102

网站会员需要登录才能在线预览,点我登录。

如何成为网站会员>>