Kriz,
DI Wolfgang
Müllner,
DI(FH)Patricia
Jasek
The Site VSWR Procedure for the Validation of EMC Emission Test
Sites in the 1 GHz to 18 GHz Frequency Range
Abstract:
Until 2007,radiated disturbance measurements in accordance with CISPR had only been
defined for the 1 GHz frequency range.The full standards which are now available
describe the measurement of emissions in the 1 GHz plus frequency range as well as
the requirements for the test site necessary to do this.A new procedure('Site VSWR')
was developed to characterise the test site which is described in the following paper.
The requirements made on the validation broadband omnidirectional antenna are
stringent.ARC developed and patented a precision antenna of this type.
Keywords:
site VSWR,CISPR 16-2-3,deviation,POD 16 antenna,POD 618 antenna